Battery tester is mainly used to detect current, voltage, capacity, internal resistance, temperature, battery cycle life, and gives the graph. Battery tester has many channels to choose from. It can start at a single point, control at a single point, and measure different types of batteries (nickel-hydrogen, nickel-cadmium, lithium-ion, etc.).
Specific test functions include: battery voltage, load voltage (voltage difference), internal resistance, short-circuit protection time, short-circuit protection recovery function, over-discharge current, charging function, identification resistance (R1, R2), code reading, capacity test (including charge and discharge test).
SPECIFICATION:
Project index Parameter index
Input Power
AC 220V ±10% / 50Hz
resolution
AD:16bit;DA:16bit
Input Resistance
≥1MΩ
Input Power
2127W
Channel Features
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure
Channel Control Mode
Independent Control
Voltage
Constant voltage
control range
25mV~5V
Minimum discharge
voltage
2.0V
Accuracy
± 0.1% of FS
Stability
± 0.1% of FS
Current
Per Channel Current
Range
Accuracy
± 0.1% of FS
Stability
± 0.1% of FS
Constant voltage
cut-off current
0.06A
Stability
± 0.1% of FS
Power
Single channel maximum output
power
150W
Stability
± 0.2% of FS
Time
Current Response
Time
Maximum current rise time 20ms
Step Time Range
≤365*24 h,
Time Form Support 00:00:00(h、min、s、ms)
Data Recording
Record Condition
Time△t:100ms
Voltage△U:10mV
Minimum current interval: 60mA
Record Frequency
10Hz
Charge
Charge Mode
Constant Current Charge、Constant Voltage Charge、
CC-CV Charge 、CP-Charge
End Condition
Voltage、Current、Relative Time、Capacity、-△V
Discharge
Discharge Mode
Constant Current Discharge CP-D CR-D
End Condition
Current、Current、Relative Time、Capacity、-△V
Pulse Model
Charge
Constant Current、Constant Power
Project index Parameter index
Discharge
Constant Current、Constant Power
Min Pulse Width
500ms
Pulse Number
Single Pulse Step Support 32 different Pulse
Charge r To Discharge
One Pulse Step Can Support Continuous Charge And Discharge Change
Stop Condition
Voltage、 Relative Time
DCIR Testing
Support Custom Access Point And Count The DCR
Cycle
Loop Measure Range
1~65535 times
Max Steps Per Loop
254
Nested Loop
Nested loop Function,Max Support 3 Layers
Protection
Software Protection
Power-down Data Protection
Setting Protection Condition,Setting Parameter:Low Voltage limit、Upper Voltage limit、Low Current limit、Upper Current limit、Delay Time
IP protection level
IP20
Voltage and Current Testing Sample
4-wire connecting
Noise
<85dB
Data Management
MySQL Database
Communication Means
TCP/IP Protocol
Data Output
EXCEL、TXT
Communication Interface
Ethernet Port
Main Channels
8
Data output mode
EXCEL 2003,2010、TXT
Communication interface
Network port
Server disk configuration
500GB
Leakage current
<5uA
Equipment Working Environment
Project index Parameter index | |||
Working Temperature Range | 0℃~40℃(within the range of 25 ± 10 ℃, ensure the measurement accuracy: the accuracy drift is 0.005% of FS / ℃) | ||
Storage Temperature Range | -10℃~50℃ | ||
Working Environment Relative Humidity Range |
≤ 70% RH (no water vapor condensation) | ||
Storage Environment Relative Humidity Range |
≤ 80% RH (no water vapor condensation) | ||
Battery Clamps |
|
||
Project index Parameter index | |||
Equipment Picture |
|
||
Picture for Reference Only, take the material object as the standard. |