Wechat:17720812054 Whatsapp:+86 13174506016 Email:David@batterymaking.com
David Yuan
18659217588
Wechat:17720812054
Whatsapp:+86 13174506016
Email:David@batterymaking.com
Item NO.:
TMAX-5V6APayment:
L/C,T/T,Western Union, PaypalLead Time:
5 daysCertificate:
CE, IOS, ROHS, SGS, UL Certificate
1. This tester can analyze polymer and cylindrical batteries from 0.1mA to 6 A, up to 5V.
2 The battery test system provides most applications in battery testing fields such as electrode materials research, battery performance test, small-scale battery formation, capability grading, battery pack testing and etc.
Project index
Parameter index
Input Power
AC 220V ±10% / 50Hz
resolution
AD:16bit;DA:16bit
Input Resistance
≥1MΩ
Input Power
425W
Channel Features
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure
Channel Control Mode
Independent Control
Voltage
Per Channel Voltage Range
Charge:25mV~5V;Discharge:1.0V~5V
Accuracy
± 0.05% of FS
Stability
0.05% of FS
Current
Per Channel Output Current Range
Range1:0.5mA~0.1A;Range2:0.1A~6A;Range3: 3A-6A
Accuracy
± 0.05% of FS
CV cut-off current
Range 1: 0.2mA Range2: 6mA; Range3: 12mA;
Stability
0.05% of FS
Power
Per Channel Output Power
30W
Stability
± 0.1% of FS
Time
Current Response Time
The Current gets to 6A Hardware Response Time is 1ms
Step Time Range
0.1s≤Single Step Time Range≤365*24 h,
Time Form Support 00:00:00(h,min,s)
Data Recording
Record Condition
Minimum Time interval:100ms
Minimum Voltage interval:10mV
Minimum Current interval:Range 1: 0.2mA Range2: 12mA
Record Frequency
10Hz
Charge
Charge Mode
Constant Current Charge,Constant Voltage Charge,
CC-CV Charge ,CP-Charge
End Condition
Voltage,Current,Relative Time,Capacity,Minimum Voltage interval
Discharge
Discharge Mode
Constant Current Discharge CP-D CR-D
End Condition
Current,Current,Relative Time,Capacity,Minimum Voltage interval
Pulse Model
Charge
Constant Current,Constant Power
Discharge
Constant Current,Constant Power
Min Pulse Width
500ms
Pulse Number
Single Pulse Step Support 32 different Pulse
Charge r To Discharge
One Pulse Step Can Support Continuous Charge And Discharge Change
Stop Condition
Voltage, Relative Time
DCIR Testing
Support Custom Access Point And Count The DCR
Cycle
Loop Measure Range
1~65535 times
Max Steps Per Loop
254
Nested Loop
Nested loop Function,Max Support 3 Layers
Protection
Software Protection
l Power-down Data Protection
l Setting Protection Condition,Setting Parameter:Low Voltage limit,Upper Voltage limit,Low Current limit,Upper Current limit,Delay Time
Voltage and Current Testing Sample
4-wire connecting
Noise
<85dB
Data Management
MySQL Database
Communication Means
TCP/IP Protocol
Data Output
EXCEL,TXT
Communication Interface
Ethernet Port
Main Channels
8
Dimensions
3U,W*D*H:480*730*130(mm)per unit
the total rack is 760*660*1960mm . The gross weight is 180KG
Additional Function
Test: Temperature; voltage
Temperature range: minus 25C-110C( Thermistor)
Temperature accuracy:± 1C
Temperature resolution:0.1C
Voltage range:-5V-5V
Voltage accuracy:± 0.1% of FS
Can set the parameter: Upper and lower limit of voltage; Upper and lower limit of temperature ;single cell voltage difference
Equipment Working Environment
Project index |
Parameter index |
Working Temperature Range |
0℃~40℃ |
Storage Temperature Range |
-10℃~45℃ |
Working Environment Relative Humidity Range |
30% ~ 80% RH |
Storage Environment Relative Humidity Range |
30% ~ 90% RH |