Item NO.:
BTS-5V20APayment:
L/C,T/T,Western Union, PaypalLead Time:
5 daysCertificate:
CE, IOS, ROHS, SGS, UL Certificate
Battery tester is mainly used to detect current, voltage, capacity, internal resistance, temperature, battery cycle life, and gives the graph. Battery tester has many channels to choose from. It can start at a single point, control at a single point, and measure different types of batteries (nickel-hydrogen, nickel-cadmium, lithium-ion, etc.).
Specific test functions include: battery voltage, load voltage (voltage difference), internal resistance, short-circuit protection time, short-circuit protection recovery function, over-discharge current, charging function, identification resistance (R1, R2), code reading, capacity test (including charge and discharge test).
SPECIFICATION:
BTS-5V20A Battery testing equipment |
|||
Equipment model: BTS-5V20A |
Battery testing equipment |
Equipment material code: CT-4008 -5V20A |
|
Index items |
Index parameters |
||
Input power |
AC 220V ±10% / 50Hz |
||
Input active power |
1418 W |
||
Resolving power |
AD:16bit;DA:16bit |
||
Input impedance |
≥1MΩ |
||
Voltage |
Constant voltage range control |
0.025V~5V |
|
Minimum discharge voltage |
2V |
||
Accuracy |
± 0.1% of FS |
||
Stability |
± 0.1% of FS |
||
Current |
Output range per channel |
0.1A~20A |
|
Accuracy |
± 0.1% of FS |
||
Constant voltage cut-off current |
0.04A |
||
Stability |
± 0.1% of FS |
||
Power |
Single channel maximum output power |
100 W |
|
Stability |
± 0.2% of FS |
||
Time |
Current response time |
Maximum current rise time 20ms |
|
Step time range |
≤(365*24)hour; time format support00:00:00.000(h、min、s、ms) |
||
Data record |
Data recording conditions |
Minimum time interval:100ms |
|
Minimum voltage interval:10mV |
|||
Minimum current interval:40mA |
|||
Recording frequency |
10Hz |
||
Charge |
Charging mode |
Constant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging |
|
Cut off conditions |
Voltage, current, relative time, capacity, - △ V |
||
Discharge |
Discharge mode |
Constant current discharge, constant power discharge, constant resistance discharge, support custom constant voltage discharge and constant current constant voltage discharge |
|
Cut off conditions |
Voltage, current, relative time, capacity |
||
Pulse mode |
Charge |
Constant current mode, constant power mode |
|
Discharge |
Constant current mode, constant power mode |
||
Minimum pulse width |
500ms |
||
Number of pulses |
A single pulse step supports 32 different pulses |
||
Charge discharge continuous switching |
A pulse step can realize continuous switching from charging to discharging |
||
Cut off conditions |
Voltage, relative time |
||
DCR test |
Support user defined point for DCR calculation |
||
Loop |
Cycle test range |
1~65535times |
|
Single cycle steps |
254 |
||
Loop nesting |
It has nested loop function, and supports up to 3 layers of nesting |
Protect |
Power down data protection |
|
With offline test function |
||
The safety protection conditions can be set, and the setting parameters include: upper voltage limit, lower voltage limit, upper current limit, lower current limit, upper capacity limit and delay time |
||
With anti reverse connection function (to be used with software) |
||
IP protection level |
Protection grade IP20 |
|
Channel characteristics |
Constant current source and constant voltage source adopt double closed loop structure |
|
Channel control mode |
Independent control |
|
Sampling of voltage and current detection |
Four wire connection |
|
Noise |
<75dB |
|
Database |
Centralized management of test data with MySQL database |
|
Communication mode of upper computer |
Based on TCP / IP protocol |
|
Data output mode |
EXCEL2003,2010、TXT |
|
Server disk configuration |
500GB |
|
Leakage current |
0.005mA |
|
Server operating system |
Windows 7、Windows 10 |
|
Communication interface |
Network port |
|
Equipment working environment requirements |
||
Index items |
Index parameters |
|
Operating temperature range |
0℃~40℃(Within the range of 25 ± 10 ℃, the measurement accuracy is guaranteed: the accuracy drift is 0.005% of FS / ℃) |
|
Storage temperature range |
-10℃~50℃ |
|
Relative humidity range of working environment |
≤70% RH(There is no condensation) |
|
Relative humidity range of storage environment |
≤80% RH(There is no condensation) |