Wechat:17720812054 Whatsapp:+86 13174506016 Email:David@batterymaking.com
David Yuan
18659217588
Wechat:17720812054
Whatsapp:+86 13174506016
Email:David@batterymaking.com
Item NO.:
CE-6002n-60V100A-HPayment:
L/C,T/T,Western Union, PaypalLead Time:
5 days
Introduction:
*Power battery simulation, C-rate test.
*Life cycle test.
*Power test, capacity test, energy density test.
*Power battery virtual distribution: charge/discharge curve fitting, battery consistency test and evaluation.
*High rate charge/discharge test.
*Power battery, serial energy-storage battery module test: single cell voltage, Single cell temperature monitoring(high-voltage equipment).
Features(some features required a customization):
*High-performance charge/discharge test platform developed for high-power battery modules(or packages).
*Adopting AC/DC、DC/DC Dual-level high frequency module design, combined with low temperature drift, high-performance multi-channel 24-bit analog-to-digital conversion chip(ADC) to achieve higher stabilize accuracy.
*High-level power density system with multi-channel integration and capable for energy recovering.
HMI operation, smart calibration.
*Multiple adaption for BMS, supports the same/different charge and discharge ports, relay/MOSBMS solution, independent CAN and RS485 communication expansion, and DBC configuration.
*Remote control available for host computer through Ethernet, channels parallel, pulse and driving simulation available.
*Man-computer integration interface design, minimized system for easy-understand operating, customized setting available, automatic reminder for termly calibration.
CE-6000 Specification
1、Model
1. Material code
CE-6002n-60V100A-H
2、Channels information
1. Channels quantity
Channels quantity in one unit
2
2. Main channel
Channel feature
Constant current source and constant voltage source dual closed loop control
Channel control mode
Independent control
Channel parallel connection
Support max 4 channels parallel mode. Pulse and SIM tests will be disabled in channels parallel mode.
3、Power grid side parameters
1.Input power
AC380V±15% 50/60±5Hz
2.Power factor
≥99%(Full load)
3.THDi
≤5%(Full load)
4.Input resistance
≥1MΩ
5.Input power
14.1KW
6.Input current
21.5A/single
7.Overall system efficiency(Max)
90%
8.Noise
≤65dB
9.Voltage and current sampling
Four-wire connection(same port for charging and discharging)
10.Power control module type
MOSFET
11.Input power wiring method
Three-phase-five wire system
12.Power input protection
Anti-surge, anti-silos, anti over or under frequency, anti over or under voltage, anti phase absence, etc.
4、Functions and performances
1. Voltage
Output range
Charge:0V~60V
Discharge:3V~60V
Min discharge voltage
3V
Accuracy
±0.02% of FS
Resolution
24bit
2. Current
Output range
0.5A~100A
Accuracy(independent range)
±0.05% of FS
CV cut-off current
100mA
Resolution
24bit
3. Power
Single channel output power
6KW
Whole machine output power
12KW
4. Time
Current response time
≤3ms
Current conversion time
≤6ms
Min. step time
0.1s
5. Charge/Discharge modes
Charge/Discharge modes
CCC, CVC, CC-CVC, CPC
CCD, CVD, CPD, CRD
Cut-off condition
Voltage, Current, ΔTime, Capacity, -ΔV
6. Simulation
Charge
Current, Power
Discharge
Current, Power
Switch
Support continuous switching between charge and discharge
Cut-off condition
Time, step line
Steps file lines
1,000,000
7. Pulse Mode
Charge
Current ,power
Discharge
Current, Power
Min pulse
100ms
Pulse counts
Up to 32
Charge and discharge switch
supported
Cut-off condition
Voltage, ΔTime
8. DCIR
DCIR by calculation
9. Safely protection
Software protection
Power off data protection
Offline mode function
Safety protection conditions can be set, including:voltage lower limit ,voltage upper limit ,current lower limit ,current upper limit ,delay time, etc.
Hardware protection
Anti-reverse connection, over-voltage, over-current, over-temperature, etc.
5、Data management and analysis
1. Step setting method
Form editing
2. Data report
Recording conditions
Minimum time interval: 10ms(connected with AUX channel:100ms)
Minimum voltage interval: 0.12V
Minimum current interval: 0.2A
Recording frequency
100Hz(connected with AUX channel:10Hz)
3. Database
MySQL database
4. Data output
Excel, Txt
5. Curve type
Templates available, customization supported
6. Bar code scanning
Support bar-code scanning function
Management and traceability of historical data
6、Communication
1. Host computer communication
TCP/IP protocol
2. Communication port
Ethernet
3. Communication baud rate of the testers
1M
4. Host computer communication baud rate
10M~100M adaptive
5. Communication setup
Set up a LAN(local area network) through switches and routers
6. Communication expansion(optional)
Support CAN, RS485 communication and BMS communication, with DBC configuration function
7、Environmental requirements, dimension and weight
1. Operation environment temperature
-10℃~40℃(When the temperature is 25±10℃, the accuracy error caused by temperature change is less than 0.005% of FS per degree)
2. Storage environment temperature
-20℃~50℃
3. Operation environment humidity
≤70% RH(no moisture condensation)
4. Storage environment humidity
≤80% RH(no moisture condensation)
5. Dimension W*D*H
600*800*900(mm)
6. Weight
about 111.1KG