Wechat:17720812054 Whatsapp:+86 13174506016 Email:David@batterymaking.com
David Yuan
18659217588
Wechat:17720812054
Whatsapp:+86 13174506016
Email:David@batterymaking.com
Item NO.:
BTS-20V10APayment:
L/C,T/T,Western Union, PaypalLead Time:
5 daysCertificate:
CE, IOS, ROHS, SGS, UL Certificate
Battery tester is mainly used to detect current, voltage, capacity, internal resistance, temperature, battery cycle life, and gives the graph. Battery tester has many channels to choose from. It can start at a single point, control at a single point, and measure different types of batteries (nickel-hydrogen, nickel-cadmium, lithium-ion, etc.).
Specific test functions include: battery voltage, load voltage (voltage difference), internal resistance, short-circuit protection time, short-circuit protection recovery function, over-discharge current, charging function, identification resistance (R1, R2), code reading, capacity test (including charge and discharge test).
SPECIFICATION:
Project index Parameter index | ||
Input Power | AC 220V ±10% / 50Hz | |
resolution | AD:16bit;DA:16bit | |
Input Resistance | ≥1MΩ | |
Input Power | 2228W | |
Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure | |
Channel Control Mode | Independent Control | |
Voltage |
Constant voltage control range |
0.1V~20V
|
Minimum discharge voltage |
2.5V | |
Accuracy | ± 0.1% of FS | |
Stability | ± 0.1% of FS | |
Current |
Per Channel Current Range |
0.05A~10A
|
Accuracy | ± 0.1% of FS | |
Stability | ± 0.1% of FS | |
Constant voltage cut-off current |
0.02A | |
Stability | ± 0.1% of FS | |
Power |
Single channel maximum output power |
200W |
Stability | ± 0.2% of FS | |
Time |
Current Response Time |
Maximum current rise time 20ms |
Step Time Range |
≤365*24 h, Time Form Support 00:00:00(h、min、s、ms) |
|
Data Recording | Record Condition | Time△t:100ms |
Voltage△U:40mV | ||
Minimum current interval: 20mA | ||
Record Frequency | 10Hz | |
Charge | Charge Mode |
Constant Current Charge、Constant Voltage Charge、 CC-CV Charge 、CP-Charge |
End Condition | Voltage、Current、Relative Time、Capacity、-△V | |
Discharge | Discharge Mode | Constant Current Discharge CP-D CR-D |
End Condition | Current、Current、Relative Time、Capacity、-△V | |
Pulse Model | Charge | Constant Current、Constant Power |
Project index Parameter index | ||
Discharge | Constant Current、Constant Power | |
Min Pulse Width | 500ms | |
Pulse Number | Single Pulse Step Support 32 different Pulse | |
Charge r To Discharge | One Pulse Step Can Support Continuous Charge And Discharge Change | |
Stop Condition | Voltage、 Relative Time | |
DCIR Testing | Support Custom Access Point And Count The DCR | |
Cycle | Loop Measure Range | 1~65535 times |
Max Steps Per Loop | 254 | |
Nested Loop | Nested loop Function,Max Support 3 Layers | |
Protection | Software Protection | Power-down Data Protection |
Setting Protection Condition,Setting Parameter:Low Voltage limit、Upper Voltage limit、Low Current limit、Upper Current limit、Delay Time | ||
IP protection level | IP20 | |
Voltage and Current Testing Sample | 4-wire connecting | |
Noise | <85dB | |
Data Management | MySQL Database | |
Communication Means | TCP/IP Protocol | |
Data Output | EXCEL、TXT | |
Communication Interface | Ethernet Port | |
Main Channels | 8 | |
Data output mode | EXCEL 2003,2010、TXT | |
Communication interface | Mesh port | |
Server disk configuration | 500GB | |
Leakage current | <5uA |
Equipment Working Environment
Project index Parameter index | |||
Working Temperature Range | 0℃~40℃(within the range of 25 ± 10 ℃, ensure the measurement accuracy: the accuracy drift is 0.005% of FS / ℃) | ||
Storage Temperature Range | -10℃~50℃ | ||
Working Environment Relative Humidity Range |
≤ 70% RH (no water vapor condensation) | ||
Storage Environment Relative Humidity Range |
≤ 80% RH (no water vapor condensation) | ||
Battery Clamps |
|
||
Project index Parameter index | |||
Equipment Picture |
|
||
Picture for Reference Only, take the material object as the standard. |