Wechat:17720812054 Whatsapp:+86 13174506016 Email:David@batterymaking.com
David Yuan
18659217588
Wechat:17720812054
Whatsapp:+86 13174506016
Email:David@batterymaking.com
Item NO.:
CE-6002n-100V60A-HPayment:
L/C,T/T,Western Union, PaypalLead Time:
5 days
Introduction:
*Power battery simulation, C-rate test.
*Life cycle test.
*Power test, capacity test, energy density test.
*Power battery virtual distribution: charge/discharge curve fitting, battery consistency test and evaluation.
*High rate charge/discharge test.
*Power battery, serial energy-storage battery module test: single cell voltage, Single cell temperature monitoring(high-voltage equipment).
Features(some features required a customization):
*High-performance charge/discharge test platform developed for high-power battery modules(or packages).
*Adopting AC/DC、DC/DC Dual-level high frequency module design, combined with low temperature drift, high-performance multi-channel 24-bit analog-to-digital conversion chip(ADC) to achieve higher stabilize accuracy.
*High-level power density system with multi-channel integration and capable for energy recovering.
HMI operation, smart calibration.
*Multiple adaption for BMS, supports the same/different charge and discharge ports, relay/MOSBMS solution, independent CAN and RS485 communication expansion, and DBC configuration.
*Remote control available for host computer through Ethernet, channels parallel, pulse and driving simulation available.
*Man-computer integration interface design, minimized system for easy-understand operating, customized setting available, automatic reminder for termly calibration.
CE-6000 Specification |
||
1、Model |
||
1. Material code |
CE-6002n-100V60A-H |
|
2、Channels information |
||
1. Channels quantity |
Channels quantity in one unit |
2 |
2. Main channel |
Channel feature |
Constant current source and constant voltage source dual closed loop control |
|
Channel control mode |
Independent control |
|
Channel parallel connection |
Support max 4 channels parallel mode. Pulse and SIM tests will be disabled in channels parallel mode.
|
3、Power grid side parameters |
||
1.Input power |
|
AC380V±15% 50/60±5Hz |
2.Power factor |
|
≥99%(Full load) |
3.THDi |
|
≤5%(Full load) |
4.Input resistance |
|
≥1MΩ |
5.Input power |
|
14.1KW |
6.Input current |
|
21.5A/single |
7.Overall system efficiency(Max) |
|
90% |
8.Noise |
|
≤65dB |
9.Voltage and current sampling |
|
Four-wire connection(same port for charging and discharging) |
10.Power control module type |
|
MOSFET |
11.Input power wiring method |
|
Three-phase-five wire system |
12.Power input protection |
|
Anti-surge, anti-silos, anti over or under frequency, anti over or under voltage, anti phase absence, etc. |
4、Functions and performances |
||
1. Voltage |
Output range |
Charge:0V~100V |
|
|
Discharge:3V~100V |
|
Min discharge voltage |
3V |
|
Accuracy |
±0.02% of FS |
|
Resolution |
24bit |
2. Current |
Output range |
0.3A~60A |
|
Accuracy(independent range) |
±0.05% of FS |
|
CV cut-off current |
60mA |
|
Resolution |
24bit |
3. Power |
Single channel output power |
6KW |
|
Whole machine output power |
12KW |
4. Time |
Current response time |
≤3ms |
|
Current conversion time |
≤6ms |
|
Min. step time |
0.1s |
5. Charge/Discharge modes |
Charge/Discharge modes |
CCC, CVC, CC-CVC, CPC |
|
|
CCD, CVD, CPD, CRD |
|
Cut-off condition |
Voltage, Current, ΔTime, Capacity, -ΔV |
6. Simulation |
Charge |
Current, Power |
|
Discharge |
Current, Power |
|
Switch |
Support continuous switching between charge and discharge |
|
Cut-off condition |
Time, step line |
|
Steps file lines |
1,000,000 |
7. Pulse Mode |
Charge |
Current ,power |
|
Discharge |
Current, Power |
|
Min pulse |
100ms |
|
Pulse counts |
Up to 32 |
|
Charge and discharge switch |
supported |
|
Cut-off condition |
Voltage, ΔTime |
8. DCIR |
|
DCIR by calculation |
9. Safely protection |
Software protection |
Power off data protection |
|
|
Offline mode function |
|
|
Safety protection conditions can be set, including:voltage lower limit ,voltage upper limit ,current lower limit ,current upper limit ,delay time, etc. |
|
Hardware protection |
Anti-reverse connection, over-voltage, over-current, over-temperature, etc. |
5、Data management and analysis |
||
1. Step setting method |
|
Form editing |
2. Data report |
Recording conditions |
Minimum time interval: 10ms(connected with AUX channel:100ms) |
|
|
Minimum voltage interval: 0.2V |
|
|
Minimum current interval: 0.12A |
|
Recording frequency |
100Hz(connected with AUX channel:10Hz) |
3. Database |
|
MySQL database |
4. Data output |
|
Excel, Txt |
5. Curve type |
|
Templates available, customization supported |
6. Bar code scanning |
|
Support bar-code scanning function |
|
|
Management and traceability of historical data |
6、Communication |
||
1. Host computer communication |
|
TCP/IP protocol |
2. Communication port |
|
Ethernet |
3. Communication baud rate of the testers |
|
1M |
4. Host computer communication baud rate |
|
10M~100M adaptive |
5. Communication setup |
|
Set up a LAN(local area network) through switches and routers |
6. Communication expansion(optional) |
|
Support CAN, RS485 communication and BMS communication, with DBC configuration function |
7、Environmental requirements, dimension and weight |
||
1. Operation environment temperature |
|
-10℃~40℃(When the temperature is 25±10℃, the accuracy error caused by temperature change is less than 0.005% of FS per degree) |
2. Storage environment temperature |
|
-20℃~50℃ |
3. Operation environment humidity |
|
≤70% RH(no moisture condensation) |
4. Storage environment humidity |
|
≤80% RH(no moisture condensation) |
5. Dimension W*D*H |
|
600*800*900(mm) |
6. Weight |
|
about 111.1KG |